BTHWX - LEAD-ACID BATTERY

  • MSDS: BTHWX
  • Manufacturer: EXIDE CORP
  • Product Name: LEAD-ACID BATTERY
  • National Stock Number: 6140-01-341-3437
Product Identification

Product ID:LEAD-ACID BATTERY
MSDS Date:09/01/1993
FSC:6140
NIIN:01-341-3437
MSDS Number: BTHWX

Responsible Party
EXIDE CORP
645 PENN STREET
READING, PA 19612-4205
US

Emergency Phone: 215-378-0500/800-424-9300(CHEMTREC)

Info Phone: 215-378-0798

Cage: 20038

Contractor
IDEA SUPPLY CO.
UNKNOW READING, PA 19612-4205 US

Telephone: 610-378-0500/0798

Cage: 0EZ40

Ingredients

LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 53%

OSHA PEL SEE 1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9394

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY (SARA III)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 0.2%

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG (SB)/M3; 9394

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ARSENIC (ORGANIC COMPOUNDS) (SARA III)

CAS: 7440-38-2

RTECS: CG0525000

Fraction By Weight: 0.003%

OSHA PEL SEE 1910.1018

ACGIH TLV: 0.01 MG/M3, A1; 9394

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


CALCIUM, METAL

CAS: 7440-70-2

RTECS: EV8040000

Fraction By Weight: 0.02%


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 0.06%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9394


SULFURIC ACID (SARA III), ELECTROLYTE

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 30-40%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9394

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


POLYPROPYLENE

CAS: 9003-07-0

Fraction By Weight: SEE #9%

Hazards

LD50 LC50 Mixture:NOT GIVEN
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL:SEVERE UPPER RESPIR & LUNG
IRRIT. INGEST:SEVERE IRRIT OF MOUTH, THROAT, ESOPHAGUS, STOMACH &
GI TRACT. SKIN: SEVERE IRRIT, BURNS, ULCERATION. EYE:SEVERE IRRIT,
BURNS.
Explanation of Carcinogenicity:CONTAINS 52% LEAD WHICH IS IARC
CARCINOGEN. CONTAINS <.1% OF ARSENIC.
Effects of Overexposure:EYE:DAMAGE TO CORNEA, BURNS, REDNESS,
BLINDNESS. INHAL:INFLAMM OF NOSE, THROAT, BRONCHIAL TUBES.
SKIN:BURNS, ULCERATION. INGEST:ABDOMINAL PAIN, NAUSEA, VOMIT,
DIARRHEA, SEVERE CRAMPING, SYSTEMIC TOXIC ITY (LEAD), FATIGUE, LOSS
OF APPETITE, MUSCULAR ACHES, WEAKNESS, SLEEP DISTURBANCES,
IRRITABILITY, ANEMIA, KIDNEY DAMAGE
Medical Cond Aggravated by Exposure:SULFURIC ACID:CAUSES LUNG DAMAGE &
AGGRAVATE PULMONARY CONDITIONS & SKIN DISEASES (ECZEMA, CONTACT
DERMATITIS). LEAD & ITS COMPOUNDS:AGGRAVATE SOME FORMS OF KIDNEY,
LIVER & NEUROLOGIC DISEASES.

First Aid

First Aid:INHAL:ACID:REMOVE TO FRESH AIR IMMED. IF BREATH DIFFIC GIVE
OXYGEN. LEAD:REMOVE FROM EXPOSURE, GARGLE, WASH NOSE & LIPS. SEE
DR. INGEST:ACID:GIVE LG AMTS OF WATER. DON'T INDUCE VOMIT. SEE DR.
SKIN:ACI D/LEAD:FLUSH W/LG AMTS OF WATER FOR @ LEAST 15MINS. REMOVE
CONTAMINATED CLOTH/SHOE COMPLETELY. EYE:ACID/LEAD:FLUSH IMMED W/LG
AMTS OF WATER FOR @ LEAST 15MINS. SEE DR.

Fire Fighting

Lower Limits:4.1% H2 GAS
Upper Limits:74.2%
Extinguishing Media:CARBON DIOXIDE, FOA, DRY CHEMICAL.
Fire Fighting Procedures:IF BATTERIES ARE ON CHARGE SHUT OFF POWER. USE
+ PRESSURE, SCBA. WATER APPLIED TO ELECTROLYTE GENERATES HEAT &
SPATTERING. WEAR ACID-RESISTANT CLOTHING.
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE HYDROGEN GAS GENERATED
DURING CHARGING & OPERATION OF BATTERIES. KEEP SPARKS/SOURCE OF
IGNITION AWAY.

Accidental Release

Spill Release Procedures:STOP FLOW.CONTAIN/ABSORB SM SPILLS W/DRY
SAND/EARTH/VERMICULITE.DON'T USE COMBUSTIBLE MATLS.CAREFULLY
NEUTRALIZE SPILLED ELECTROLYTE W/SODA ASH, SODIUM BICARBONATE,
LIME, ETC.WEAR ACID- RESISTANT CLOT H/BOOTS/GLOVES/FACESHIELD.DON'T
DISCHARGE UNNEUTRA
Neutralizing Agent:SODA ASH, SODIUM BICARBONATE, LIME, ETC.

Handling

Handling and Storage Precautions:STORE BATTERIES IN COOL,DRY
WELL-VENTILATED AREAS W/IMPERVIOUS SURFACES & ADEQUATE CONTAINMENT
IN EVENT OF SPILL. AVOID DAMAGE TO CONTAINERS.
Other Precautions:STORE ALSO UNDER ROOF FOR PROTECTION AGAINST ADVERSE
WEATHER CONDITIONS. SEPARATE FROM INCOMPATIBLE MATERIALS. STORE &
HANDLE ONLY IN AREAS W/ADEQUATE WATER SUPPLY & SPILL CONTROL. KEEP
AWAY FROM FIRE , SPARKS & HEAT.

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS. WHEN
CONCENTRATIONS OF SULFURIC ACID MIST ARE KNOWN TO EXCEED PEL USE
NIOSH/ MSHA-APPROVED RESPIRATORY PROTECTION.
Ventilation:NEEDS TO BE A WELL-VENTILATED AREA. IF MECHANICAL
VENITLATION IS USED, COMPONENTS MUST BE ACID-RESISTANT.
Protective Gloves:RUB;PLAST ACID-RESI W/ELBOW-LEN GAUNTLET
Eye Protection:CHEM GOGGLES OR FACE SHIELD.
Other Protective Equipment:ACID-RESISTANT APRON. UNDER SEVERE EXPOSURE
OR EMERG CONDITONS WEAR ACID-RESISTANT CLOTH/BOOTS. EYEWASH
STATIONS. SHOWER
Work Hygienic Practices:HANDLE BATTERIES CAUTIOUSLY TO AVOID
SPILLS.MAKE CERTAIN VENT CAPS ARE ON SECURELY. AVOID CONTACT
W/INTERNAL COMPONENTS.
Supplemental Safety and Health
LEAD CMPDS:AVOID CONTACT W/STRONG ACIDS, BASES, HALIDES, HALOGENATES,
POTASSIUM NITRATE, PERMANGANATE, PEROXIDES, NASCENT HYDROGEN,
REDUCING AGENTS. PHYSICAL DATA FOR ELECTROLYTE.

Chemical Properties

HCC:C1
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:203F,95C
Vapor Pres:17-11
Vapor Density:>1
Spec Gravity:1.230-1.350
Evaporation Rate & Reference:<1, BUAC=1
Solubility in Water:COMPLETE
Appearance and Odor:MFGED ARTICLE. NO APPARENT ODOR. ELECTROLYTE:CLEAR
LIQ W/SHARP,PUNGENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
COMBUSTIBLE & ORG MTRLS.STRONG REDUCING AGENTS & OXIDIZERS, METALS
(GIVING TOXIC SO & H2 GAS),SULFUR TRIOXIDE GAS,WATER.
Stability Condition to Avoid:PROLONGED OVERCHARGE; SOURCES OF IGNITION.
DO NOT ALLOW METALLIC MATRL TO SIMULTANEOUSLY CONTACT NEG & POS
TERMINALS.
Hazardous Decomposition Products:SULFUR TRIOXIDE,CARBON
MONOXIDE,SULFURIC ACID MIST,SO2,H2, TOXIC METAL FUME, TOXIC ARSINE
GAS.

Disposal

Waste Disposal Methods:SENT SPENT BATTERIES TO 2ND PB SMELTER FOR
RECYCLING.PLACE NEUTRA SLURRY INTO SEALED CONTAINER;DISPOSE AS
APPLICABLE. LG H2O-DILUTED SPILLS AFT NEUTRA & TEST SHOULD BE
MANAGED IAW LOC/STATE/FED REGU.C ONSULT STATE ENVIRO AGENCY &/OR
FED EPA.EPA:D002.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.